Uniform Needlestick and Sharp Object Injury Report
48 Hospitals, 2003
Total Cases: 1,728
Total Average Daily Census: 7,239
|
JOB CATEGORY |
||
|
M.D. (attending/staff) |
182 |
10.6% |
|
M.D. (intern/resident/fellow) |
195 |
11.4% |
|
Medical student |
17 |
1.0% |
|
Nurse RN/LPN/NP/CRNA/Midwife |
649 |
37.8% |
|
Nursing student |
9 |
0.5% |
|
Respiratory therapist |
31 |
1.8% |
|
Surgery attendant |
156 |
9.1% |
|
Other attendant |
39 |
2.3% |
|
Phlebotomist/Venipuncture/I.V. team |
92 |
5.4% |
|
Clinical laboratory worker |
42 |
2.4% |
|
Technologist (non-lab) |
80 |
4.7% |
|
Dentist |
2 |
0.1% |
|
Dental hygienist |
1 |
0.1% |
|
Housekeeper |
43 |
2.5% |
|
Laundry worker |
3 |
0.2% |
|
Paramedic |
2 |
0.1% |
|
CNA/HHA |
33 |
1.9% |
|
Security |
2 |
0.1% |
|
Other student |
25 |
1.5% |
|
Other |
112 |
6.5% |
|
(1,715 records) |
||
|
PLACE OF OCCURRENCE |
||
|
Where did the injury occur in the institution? |
||
|
Patient room/Ward |
463 |
26.9% |
|
Outside patient room |
17 |
1.0% |
|
Emergency department |
173 |
10.1% |
|
Intensive/Critical care unit |
92 |
5.4% |
|
Operating room/Recovery |
576 |
33.5% |
|
Outpatient clinic/office |
78 |
4.5% |
|
Blood bank |
2 |
0.1% |
|
Venipuncture center |
20 |
1.2% |
|
Dialysis facility |
5 |
0.3% |
|
Procedure room |
89 |
5.2% |
|
Clinical laboratories |
27 |
1.6% |
|
Autopsy/Pathology |
15 |
0.9% |
|
Service/Utility area |
25 |
1.5% |
|
Labor and delivery |
53 |
3.1% |
|
Home-care |
6 |
0.3% |
|
Other |
78 |
4.5% |
|
(1,719 records) |
||
|
SOURCE PATIENT |
||
|
Was the source patient known/identifiable? |
||
|
Yes |
1,575 |
91.9% |
|
No |
99 |
5.8% |
|
Unknown |
31 |
1.8% |
|
N/A |
8 |
0.5% |
|
(1,713 records) |
||
|
ORIGINAL USER |
||
|
Was the injured worker the original user of the sharp item? |
||
|
Yes |
1,016 |
59.7% |
|
No |
638 |
37.5% |
|
Unknown |
19 |
1.1% |
|
N/A |
28 |
1.6% |
|
(1,701 records) |
||
|
CONTAMINATION |
||
|
Was the sharp item: |
||
|
Contaminated |
1,559 |
91.2% |
|
Uncontaminated |
34 |
2.0% |
|
Unknown |
116 |
6.8% |
|
(1,709 records) |
||
|
ORIGINAL PURPOSE |
||
|
For what purpose was the sharp item originally used? |
||
|
Unknown, N/A |
84 |
4.9% |
|
Injection, IM/Subcutaneous |
358 |
20.9% |
|
Heparin or saline flush |
14 |
0.8% |
|
Other injection into IV site or port |
51 |
3.0% |
|
Connect IV line |
3 |
0.2% |
|
Start IV or heparin lock |
87 |
5.1% |
|
Draw venous blood sample |
253 |
14.7% |
|
Draw arterial blood sample |
50 |
2.9% |
|
Obtain body fluid/tissue sample |
34 |
2.0% |
|
Fingerstick/heel stick |
29 |
1.7% |
|
Suturing |
357 |
20.8% |
|
Cutting (surgery) |
156 |
9.1% |
|
Electrocautery |
13 |
0.8% |
|
Contain specimen/pharmaceutical |
14 |
0.8% |
|
Place arterial line |
33 |
1.9% |
|
Fingernails/teeth |
0 |
0.0% |
|
Drilling |
11 |
0.6% |
|
Other |
169 |
9.8% |
|
(1,716 records) |
||
|
HOW INJURY OCCURRED |
||
|
Did the injury occur: |
||
|
Before use |
20 |
1.2% |
|
During use |
634 |
37% |
|
Between steps |
229 |
13.4% |
|
Disassembling |
50 |
2.9% |
|
Preparing for reuse |
21 |
1.2% |
|
Recapping |
57 |
3.3% |
|
Withdrawing from resistant material |
34 |
2.0% |
|
Other after use, before disposal |
292 |
17.0% |
|
Item left on disposal container |
4 |
0.2% |
|
Putting item into disposal container |
94 |
5.5% |
|
After disposal, item protruding from disposal container |
24 |
1.4% |
|
Pierced side of disposal container |
4 |
0.2% |
|
Pierced trash/side of inappropriate disposal container |
31 |
1.8% |
|
Restraining patient |
14 |
0.8% |
|
Device left on floor/bed/table/inappropriate place |
101 |
5.9% |
|
Other |
104 |
6.1% |
|
(1,713 records) |
||
|
DEVICE |
||
|
What device or item caused the injury? |
||
|
Disposable syringe |
530 |
31.7% |
|
Pre-filled cartridge syringe |
25 |
1.5% |
|
Blood gas syringe |
21 |
1.3% |
|
Syringe, other type or not sure which |
19 |
1.1% |
|
Needle on IV line/tubing |
7 |
0.4% |
|
Winged needle IV set |
127 |
7.6% |
|
IV catheter (stylet) |
71 |
4.3% |
|
Vacuum tube blood collection needle/holder |
64 |
3.8% |
|
Spinal or epidural needle |
6 |
0.4% |
|
Unattached hypodermic needle |
9 |
0.5% |
|
Arterial catheter introducer needle |
7 |
0.4% |
|
Central line catheter introducer needle |
8 |
0.5% |
|
Drum catheter needle |
3 |
0.2% |
|
Other vascular catheter needle |
4 |
0.2% |
|
Other non-vascular catheter needle |
1 |
0.1% |
|
Needle, not sure what kind |
16 |
1.0% |
|
Other needle |
40 |
2.4% |
|
. |
||
|
Lancet |
24 |
1.4% |
|
Suture needle |
347 |
20.8% |
|
Scalpel, reusable |
67 |
4.0% |
|
Razor |
8 |
0.5% |
|
Pipette (plastic) |
0 |
0.0% |
|
Scissors |
13 |
0.8% |
|
Bovie electrocautery device |
14 |
0.8% |
|
Bone cutter |
3 |
0.2% |
|
Bone chip |
4 |
0.2% |
|
Towel clip |
4 |
0.2% |
|
Microtome blade |
1 |
0.1% |
|
Trocar |
8 |
0.5% |
|
Vacuum tube, plastic |
0 |
0.0% |
|
Specimen/test tube, plastic |
0 |
0.0% |
|
Fingernails/teeth |
13 |
0.8% |
|
Scalpel, disposable |
67 |
4.0% |
|
Retractor, skin/bone hooks |
14 |
0.8% |
|
Staples/steel sutures |
6 |
0.4% |
|
Wire |
15 |
0.9% |
|
Pin |
9 |
0.5% |
|
Drill bit/bur |
2 |
0.1% |
|
Pickups/forceps/hemostats/clamps |
6 |
0.4% |
|
Sharp item, not sure what kind |
18 |
1.1% |
|
Other item |
43 |
2.6% |
|
. |
||
|
Medication ampule |
3 |
0.2% |
|
Medication vial (small) |
0 |
0.0% |
|
Pipette, glass |
1 |
0.1% |
|
Vacuum tube, glass |
5 |
0.3% |
|
Specimen/test tube, glass |
7 |
0.4% |
|
Capillary tube |
0 |
0.0% |
|
Glass slide |
5 |
0.3% |
|
Glass item, not sure what kind |
0 |
0.0% |
|
Other glass item |
5 |
0.3% |
|
(1,670 records) |
||
|
SAFETY DESIGN |
||
|
If the item causing the injury was a needle, was it a safety design with a shielded, recessed, or retractable needle? |
||
|
Yes |
519 |
31.6% |
|
No |
936 |
56.9% |
|
Unknown |
189 |
11.5% |
|
(1,644 records) |
||
|
IF SAFETY DESIGN: |
||
|
If the item causing the injury was a safety design with a shielded, recessed, or retractable needle, was the safety mechanism activated? |
||
|
Yes, fully |
44 |
9.0% |
|
Yes, partially |
100 |
20.5% |
|
No |
344 |
70.5% |
|
(488 records) |
||
|
IF SAFETY DESIGN: |
||
|
If the item causing the injury was a safety design with a shielded, recessed, or retractable needle, did the injury happen? |
||
|
Before activation |
285 |
63.3% |
|
During activation |
104 |
23.1% |
|
After activation |
61 |
13.6% |
|
(450 records) |
||
|
SEVERITY OF INJURY |
||
|
Was the injury: |
||
|
Superficial |
974 |
57.3% |
|
Moderate |
675 |
39.7% |
|
Severe |
52 |
3.1% |
|
(1,701 records) |
||
|
BODY PART |
|
|
Right hand |
631 |
|
Left hand |
960 |
|
Arm |
50 |
|
Face/Head |
1 |
|
Chest/Front |
5 |
|
Back |
1 |
|
Leg |
34 |
|
Foot and ankle |
7 |
|
(1,689 records) |
|