Add-Mix Eclipse Antibiotic
- Wash hands, clean work area and gather supplies
- 10cc syringe with needle, the vial of fluid for reconstitution, eclipse ball, alcohol prep pads, and 2 pre-filled saline syringes. Prepare two saline syringes (push air out)
- Draw up 10cc of fluid from vial of fluid
- After cleansing the Medication bottle cap inject the 10cc of fluid into the medication bottle
- Mix antibiotics by gently rolling between hands until medication is dissolved
- After cleansing medication bottle cap with alcohol prep pad withdraw medication from bottle using 10cc syringe. Remove needle from end of syringe and dispose of properly
- Remove cap from end of eclipse ball and inject the medication into the ball
- Gently shake the ball a couple of times to mix the medication in the ball
- Flush port with saline
- Connect tubing on eclipse ball to PICC port, unclamp both clamps and infuse medication
- When complete, clamp PICC port, clamp tubing and disconnect
- Wipe port with alcohol pad
- Flush vigorously with the 10 cc Saline syringe using the “push-pause method,” clamp PICC port and remove syringe
- KEEP ON SCHEDULE!
SAS method:
Saline – Antibiotic – Saline
Change PICC dressing once a week or if it becomes wet or soiled, every 48 hours if gauze is used.
Continuum Home Health Care 1-800-336-4040 or 434-297-7555